  page 1 of 5 dc/dc converters tep 200wir series, 180 C 240 watt features chassis mount with screw terminal block including emi flter to meet en 55022, class a ultra wide 4:1 input voltage ranges 8.5C36, 16.5C75, 43C160 vdc en 50155 approval for railway applications very high effciency up to 91% no minimum load soft start under voltage lock-out circuit ajustable output voltage +10/-20% sense line remote on/off input reverse input voltage protection over temperature protection 3-year product warranty the tep 200wir series is a family of isolated high performance dc-dc conver - ter modules with ultra-wide 4:1 input voltage ranges. they come in chassis mount version with screw terminal block and with integrated emi input flter to meet en 55022 class a. a very high effciency allows full power operation at 25c with only 100 lfm air fow couling and operation at 60c with only 40% power derating. the very wide input voltage range and reverse input voltage protection make these converters interesting solution for battery operated systems. typical applications are in telecom/datacom, industry control and railway systems for on board power distribution. order code input voltage output voltage output current max. effciency typ. tep 200-2412wircmf 12 vd c 15 a 89 % tep 200-2413wircmf 8.5 C 36 vdc 15 vd c 12 a 90 % tep 200-2415wircmf (24 vdc nominal) 24 vdc 7. 5 a 90 % tep 200-2416wircmf 28 vdc 6.5 a 90 % tep 200-2418wircmf 48 vdc 3.7 a 89 % tep 200-4812wircmf 12 vd c 18 a 90 % tep 200-4813wircmf 16.5 C 75 vdc 15 vd c 14 a 91 % tep 200-4815wircmf (48 vdc nominal) 24 vdc 9 a 90 % tep 200-4816wircmf 28 vdc 7. 5 a 91 % tep 200-4818wircmf 48 vdc 4.5 a 90 % tep 200-7212wircmf 12 vd c 20 a 89 % tep 200-7213wircmf 43 C 160 vdc 15 vd c 16 a 90 % tep 200-7215wircmf (110 vdc nominal) 24 vdc 10 a 89 % tep 200-7216wircmf 28 vdc 8.5 a 90 % tep 200-7218wircmf 48 vdc 5 a 89 % standard models tep-mk1 din-rail mounting kit (incl. mounting screws) models with 3.3 vdc or 5.0 vdc output models with 53 vdc output (input voltage range 33 - 75 vdc) on demand models with 2:1 input voltage ranges: 8.5-22, 16.5-36, 33-75 vdc (only to optimize cost at high volumes) models for pcb mount (emi filter not included), optional heatsink and chokes for external flter negative (passive = off) remote on/off function (standard is passive = on) options http://www.tracopower.com
page 2 of 5 input specifications input current at no load (nominal input voltage) 24 v, 12 & 15 vdc models: 30 ma typ. 24 v, 24 vdc model: 35 ma typ. 24 v, 28 vdc model: 40 ma typ. 24 v, 48 vdc model: 45 ma typ. 48 v, 28 & 48 vdc models: 25 ma typ. 48 v, other models: 20 ma typ. 110 v, 28 & 48 vdc models: 15 ma typ. 110 v, other models: 10 ma typ. start-up voltage 24 v models: 9.0 vdc max. 48 v models: 18 vdc max. 110 v models: 43 vdc max. under voltage shut down (lock-out circuit) 24 v models: 7.3 C 8.1 vdc 48 v models: 15.5 C 16.3 vdc 110 v models: 33.0 C 36.0 vdc surge voltage (1 sec. max.) 24 v models: 50 vdc 48 v models: 100 vdc 110 v models: 185 vdc conducted noise en 55022 class a without external components emc immunity en 50121-3-2 C esd (electrostatic discharge) en 61000-4-2, air 8 kv, contact 6 kv, perf. criteria a C radiated immunity en 61000-4-3, 20 v/m, perf. criteria a C fast transient / surge (with external input capacitor) en 61000-4-4, 2 kv, perf. criteria a en 61000-4-5, 2 kv perf. criteria a, 24 / 48v models: chemi-con ky 200 f, 100 v, esr 48 mohm 110 v models: ruby-con bxf 100 f, 250 v C conducted immunity en 61000-4-6, 10 vrms, perf. criteria a reverse voltage protection parallel diode ut recommended input fuse (slow blow) 24 v models: 20 a 48 / 110 v models: 10 a output specifications voltage set accuracy (at full load, nominal input) 1 % output voltage adjustment +10 % / C20 % by external resistor see application note regulation C input variation vin min. to vin max. 0.1 % max. C load variation (0 C 100 %) 12 / 15 vdc models: 0.25 % max. 24 C 48 vdc models: 0.2 % max. temperature coefficient 0.02 %/k minimum load not required remote sense 10 % max. of vout nom. (trim up value to subtract) ripple and noise (20 mhz bandwidth) 12 / 15 vdc models: 100 mvp-p typ. 24 / 28 vdc models: 200 mvp-p typ. 48 vdc models: 300 mvp-p typ. start up time (nominal vin and constant resistive load) 75 ms typ. (at power on or remote on/off) transient response (25 % load step change) 200 s typ., 250 s max. output current limitation at 120 C 150 % of iout max. over voltage protection at 115 C 130 % of vout nom. short circuit protection indefinite, automatic recovery. dc/dc converters tep 200wir series 180 C 240 watt http://www.tracopower.com
page 3 of 5 general specifications temperature ranges C operating (ambient) C40c to +75c C case temperature +115 c m a x . C storage C40c to +105c derating (convection cooling) depending on installation! guideline values: see application note over temperature protection at +120c thermal shock, mechanical shock & vibration en 61373, mil-std-810f C test conditions www.tracopower.com/products/mil810.pdf humidity (non condensing) 95 % rel h max. reliability, calculated mtbf (mil-hdbk-217f, at +70c, ground benign) 300000 h isolation voltage (60sec.) C input/output 2250 vdc (basic insulation) C input/case 16 0 0 v d c isolation capacitance C input/output 2500 pf max. isolation resistance C input/output (500 vdc) >1 gohm min. switching frequency 250 khz typ. (puls width modulation) safety standards C ul online certification e188913, qqgq2 ul 60950-1 2nd edition + am1 iec/en 60950-1 C railway immunity en 50155, C flamability identified acc. en45545-2 C certification documents www.tracopower.com/overwiew/tep200wir remote on/off C positive logic (standard) C on: 3 to 12 vdc or open circuit C off: 0 to 1.2 vdc or short circuit pin 1 and 3 C negative logic (option) C on: 0 to 1.2 vdc or short circuit pin 1 and 3 C off: 3 to 12 vdc or open circuit C off idle current: 3 ma environmental compliance C reach www.tracopower.com/overview/tep200wir C rohs rohs directive 2011/65/eu application note: www.tracopower.com/products/tep200wir-application.pdf dc/dc converters tep 200wir series 180 C 240 watt max. capacitive load [f] 12 vd c 15 vd c 24 vdc 28 vdc 48 vdc 24 vdc input models 1250 0 8000 3100 2300 770 48 vdc input models 15000 9300 3700 260 0 930 110 vdc input models 1660 0 1060 0 4100 3000 1000 http://www.tracopower.com all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated.
page 4 of 5 dimensions in inch, () = mm tolerances 0.02 (0.5) pin pich tolerances 0.01 (0.25) mounting hole pich tolerances 0.01 (0.25) the screw 1 locked torque:max 11.2kgf-cm/1.14n-m the screw 2 locked torque:max 5.2kgf-cm/0.51n-m the screw 3 locked torque:max 16.8kgf-cm/1.64n-m pin-out *sense line to be connected to the output either at the module or at the load under regard of polarity. weight: 287 g (10.12o z ) dimensions general specifications casing material 24 vin & 48 vin models: metal 110 vin models: aluminium base-plate with plastic casing potting material silicone (ul94v-0 rated) base material fr4 dc/dc converters tep 200wir series 180 C 240 watt 1.33 (33.8) screw 1 screw 2 screw 3 1.53 (38.8) pin 1 C vin 2 nc 3 remote on/off 4 + vin 5 C vout 6 C sense* 7 trim 8 + sense* 9 + vout http://www.tracopower.com
page 5 of 5 options rev. july 20. 2015 dc/dc converters tep 200wir series 180 C 240 watt tep-mk1 din-rail clip for chassis mount models 1.33(33.8) 1.53(38.8) 1.87(47.5) sp ec i?cati ons can be changed wi thout noti ce! make sure you are using the latest documentation, downloadable at www.tracopower. com www .tracopower. com


▲Up To Search▲   

 
Price & Availability of TEP200-2412WIRCMF

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X